Emission samplers that combine expertise, cutting-edge technology, and innovative ideas to create advanced systems for stack emission testing. These state-of-the-art solutions make even the most complex operations, such as isokinetic sampling, much simpler.
QB1/QB1e
Portable constant flow samplers | Emission samplers
The QB1 is a family of portable constant flow samplers, designed for use in a variety of air sampling applications requiring low to mid-flow capabilities.
Built with the everyday technician in mind, the QB1 is easy to use, rugged, and reliable. It features built-in protections for particulate matter and liquids, which are the primary causes of damage to the pump and dry gas meter.
For those needing manual isokinetic sampling, the QB1e line can be synchronised with ST2 speed and flow meter.
All versions of the QB1 are capable of automatic pressure drop compensation, ensuring high flow constance even during long-term operations.
Equipped with a dry gas meter, high precision flowmeter, and thermometer for volume normalisation, the QB1 meets industry standards. Additionally, the pneumatic circuit has been designed to eliminate flow pulsations resulting from the use of diaphragm pumps.
Choose the QB1 for reliable and precise ambients air samplers in a portable and convenient package.
Meets and exceeds the requirements of UNI EN 12919, standard for environmental samplers and for ISO EN 9096, EN 14385 and EN 13649 emission sampling methods:
-
- PM10 and PM2.5 (ISO23210 VDI2066/10)
- HCl (EN1911, EPA50, EPA51)
- Dust (EN 13 284-1 and EPA5)
- Heavy metals (EN14385 and EPA 60)
- Insitu Velocity and Flow rate determination in accordance with EN 16911-1 and EN 15259
MAIN FEATURES
Constant flow rate | Automatically compensates for pressure drops |
Highly versatile | Can be used in various applications, from emissions testing to industrial hygiene |
“Leak-free” diaphragm used to pump resistant to aggressive compounds | Offers the option of using rotary pumps |
Compact, ergonomic design | Offers exceptional strength with low weight |
ST2
Velocity and flow meter for chimneys | Emission samplers
The ST2 is a flow meter and velocity sensor designed to work with all available Pitot tubes in chimneys. It is a unique device that simplifies the evaluation of fluid-dynamic stack conditions while also having a compact and lightweight design, making it easy to transport and use at high altitudes.
The development of ST2 was aimed at creating a solution that combines functionality and practicality.
Meets and exceeds the requirements of EN13284 and ISO9096:
-
- PM10 and PM2.5 (ISO23210 VDI2066/10)
- HCl (EN1911, EPA50, EPA51)
- Dust (EN 13 284-1 and EPA5)
- Heavy metals (EN14385 and EPA 60)
- Insitu Velocity and Flow rate determination in accordance with EN 16911-1 and EN 15259
MAIN FEATURES
Compatibility with all available Pitot tubes in chimneys | Ability to measure both velocity and flow |
High accuracy and repeatability of measurements | Compact and lightweight design for easy transport and use at high altitudes |
Easy-to-read backlit LCD display with various measurement units available | Rugged and durable construction for use in harsh environments |
Data logging capabilities with internal memory storage and USB port for external storage | Easy calibration procedure for ensuring accurate readings |
ST5
Portable Isokinetic Sampler | Emission samplers
The ST5® is an automatic isokinetic stack sampler dedicated to the determination of particulate matter and chemical pollutants including but not limited to: fine dust, metals, VOCs, HAPs…
The ST5® can be used both for isokinetic and constant flow sampling. ST5® is available with or without the front end sampling equipment as well as a replacement for existing sampling controllers.
The ST5® automatically set the correct isokinetic flow rate measuring in real time the differential pressure and temperature in stack, it also evaluate flue gas velocity and flow rates in accordance to the regulatory methods. Available in two flow versions (4.5 m3/h and 8.5 m3/h), the ST5® grants high accuracy and traceability in every measure or calibration. A liquid detector ensures safe and reliable operations by preventing the introduction of condensate in the sampling line.
A large LCD screen provides stack testers with an efficient interface and all the data essential to the sampling operations. It’s possible to export sampling parameters and calibration through USB 2.0 with PCs, compatible Notebooks during and/or after sampling opeartions. ST5® automatic isokinetic stack sampler complies with the most diffused standards especially when sampling micro-pollutants in low concentration and matches today’s stack testers demands in terms of accuracy, data management and efficiency of operation.
Meets and exceeds the requirements of UNI EN 13284, EN 1948-1, EN 14385, EN 13211and USEPA Method 2, Method 5, Method 17:
-
- PM10 and PM2.5 (ISO23210 VDI2066/10)
- HCl (EN1911, EPA50, EPA51)
- Dust (EN 13 284-1 and EPA5)
- Heavy metals (EN14385 and EPA 60)
- Insitu Velocity and Flow rate determination in accordance with EN 16911-1 and EN 15259
MAIN FEATURES
Automatic Isokinetic Sampler designed for source testing | Compact design and universal applicability |
Versatile pollutant sampling | Advanced built in software with touchscreen interface with large LCD interface |
Fast and accurate isokinetic flow mode | Robust filed proof casing, easy handling, light weight |
USB 2.0 and wireless Bluetooth | Remote control capability – Integration with smartphone and tablets |
Preset and user defined storage method | Timer control configuration included calibration capability |
ST5 Evo
Portable Automatic Isokinetic Stack Sampler | Emission samplers
Next generation automatic Isokinetic sampler dedicated to the determination of particulate matter and chemical pollutants realized in split version. The ST5 Evo has the same operational features of the ST5 but, respect to the ST5 offers several practical and economical advantages, thanks to the separated pump.
Meets and exceeds the requirements of UNI EN 13284, EN 1948-1, EN 14385, EN 13211and USEPA Method 2, Method 5, Method 17:
-
- PM10 and PM2.5 (ISO23210 VDI2066/10)
- HCl (EN1911, EPA50, EPA51)
- Dust (EN 13 284-1 and EPA5)
- Heavy metals (EN14385 and EPA 60)
- Insitu Velocity and Flow rate determination in accordance with EN 16911-1 and EN 15259
MAIN FEATURES
Split Automatic Isokinetic Sampler designed for source testing | Compact design and universal applicability, easy handling, light weight |
Versatile pollutant sampling | Advanced built in software with large LCD screen |
Efficient system set up: Only the 8 kg control unit is required at the sampling point | USB 2.0 for data download and firmware upgrade |
Secured Sampling Operations with built-in liquid detector to prevent condensates introduction into the system | Pre-configured controller with user defined storage method and Pitot tube library |
Ease of access enabling fast and easy routine maintenances | Timer control configuration included calibration capability |
Velocity and Flow rate as per EN and USEPA standards with swirl angle evaluation and WAF correction | Remote control capability from PC, smartphone or tablet |
CF1/CF1-UR
Flow Calibrator | Emission Samplers
State-of-the art flow calibrator that verifies and calibrates personal, environmental, or emissions samplers.
Flow rage available
- from 0.45 nl/min to 45 nl/min
- from 0.050 nl/min to 5.000 nl/min
The CF1 is a versatile device capable of calibrating no only the flow rate of the samplers but also ambient pressure, ambient temperature (UR version), relative humidity, and the volume of air passing through the cell. With the CF1, you can perform multiple calibrations using just one device.
The CF1 is also available in the CF1-UR version, which features an external sensor for measuring ambient temperature and relative humidity of the air.
Meets and exceeds the requirements of EN 12341 and EN 16450 standards:
-
- PM10 and PM2.5 (ISO23210 VDI2066/10)
- HCl (EN1911, EPA50, EPA51)
- Dust (EN 13 284-1 and EPA5)
- Heavy metals (EN14385 and EPA 60)
- Insitu Velocity and Flow rate determination in accordance with EN 16911-1 and EN 15259
MAIN FEATURES
Measures the flow rate in real-time, both during suction an delivery | Displays the measurement data in its screen and can acquire the data in both gas conditions (Pamb and Tgas) or normalized conditions. |
The UR version of the CF1 is equipped with a combined external sensor for measuring relative humidity and ambient temperature | Can provide flow rate data in both current and anhydrous conditions |
Equipped with ambient temperature and pressure sensors | Can be used to calibrate these parameters on samplers |
CF1 features an integrated flow rate reading that measures the volume of gas sampled during a test, whether under normal or current conditions | This feature also enable to utilize CF1 for verifying the reading of volumetric meters. |
Supplied with CF1-Link software and USB key for wireless connection to a windows PC. | Allows the visualisation of instantaneous data and downloading the acquired data. |
4000 mA rechargeable lithium polymer batteries with anatomy up to 8 hours. | USB Type-C power port enables to recharge directly on the field or connect to a power bank to extent the equipment autonomy. |
TARGETED POLLUTANTS
POPs – persistent organic pollutants
POPs have been discovered to be the relevant part of emissions to the environment causing health effects, including dioxins (PCCD/F), polychlorinated biphenyls (PCBs), polyaromatic hydrocarbons (PAHs), hexachlorobenzene (HCB) and others. These compounds have a high stability, low volatility and are degraded very slowly. Due to the lipophilic character, an accumulation in the human body takes place.
Fine & Coarse dust
Fine dust is the portion of solids in gases being the focus of concern for pulmonary health effects. ParTrace® cartridges trace the fine dust fraction of general concern, PM10, PM2.5, PM1, and splits them in the respective fractions within one sampling run.
Volatile Organics Compounds
Odour indicator Components